Products List
Home | Products | About Us|Contact Us
Home » Products » Flameproof Transformer » Flameproof Mining Movable Substation QF-2

Flameproof Mining Movable Substation

Flameproof Mining Movable Substation QF-2

Description of Flameproof Mining Movable Substation:
This series flameproof substation we manufactured in China is a kind of high-quality explosion-proof motors that being composed of a flameproof dry-type transformer, explosion-proof high-voltage load switch or high-voltage vacuum switch and explosion-proof low-pressure feeder switch or low-pressure protection box. Furthermore, this flameproof substation substation can also be used as power supply of transforming device for various underground coal mining equipments because it can still runs even in a 3-phase power system with rated frequency 50Hz, rated primary voltage 10KV or 6KV.

Characteristics of Flameproof Mining Movable Substation:
1.With optimized short-circuit, over-loaded, earth leakage and under-voltage protection functions
2.There is electrical interlocking between high-voltage switch and low-voltage switch, and between high voltage switch and upper-level high-voltage power distribution devices
3. The high-voltage switch has cover-opening electrical interlocking function, and the movable transformer has over-temperature alarming function.

Applications of Flameproof Mining Movable Substation:
This flameproof mining movable substation is suitable for underground coal mines or other sites, where the explosion may be latent.

Working Conditions of Flameproof Mining Movable Substation:
1) Local altitude should not surpass 1000m;
2) Ambient temperature:
Max.temperature:+40℃
Max. Daily mean temperature:+30℃
Max. Annual mean temperature:+20℃
Min. Temperature:-5℃
3) Air relative humidity is no more than 95%(at +25℃);
4) In underground mines with methane, gas and mineral dust, as well as explosive hazards;
5) Environment without intense vibration, shake and inclined angle with vertical interface should not surpass 15°;
6) Sites without gas and steam, which will be erosive to metal and destructive to insulation;
7) Places without water drops;
8) Waveforms of power voltage approaches to sine wave;
9) The voltage of 3-phase power is approximately symmetrical.

Sincerely welcome to contact us for more information on our explosion-proof motors!

Feedback Form
Other Products
  • Explosion-proof Three-phase Induction Motor for Underground Coal MiningAccording to the requirements of < Electrical Apparatus for Explosive Gas Atmosphere Part 1: General Request> and< Electrical Apparatus for Explosive Gas Atmosphere Part 2: Flameproof Enclosure 'D'> of GB3836.2-2000, these Explosion-proof Three-phase Induction Motors for Underground Coal Mining ...
  • Explosion-proof Three-phase Induction Motor for Ventilation BlowerThis explosion-proof three-phase induction motor for ventilation blower (frame size 63-355) we manufactured in China can be made into a flameproof motor according to the application requirements of GB3836.1-2000 < Electrical Apparatus for Explosive Gas Atmosphere Part 1: General Request> and ...
  • Flameproof Dry-type Transformer for Mining QF-1This series flameproof dry-type transformer is an excellent explosion-proof motor that we strongly recommend to you, as it adopts air cooling with the transformer being installed out of the housing, so the internal heat will be transmitted to the outer by air convection and radiation, this resulting in a poor heat ...